Bushranger Specifications and Installation Details
Large Bushranger MK2
| A width mm |
B depth mm |
C back to flue centre mm |
overall height mm |
WEIGHT approx. | EMISSION FACTOR g/kg | HEATING CAPACITY approx. |
| 630 | 600 | 150 | 920 | 124 kg | 2.3 | 30 Sq |
| G cnr to wall mm |
R rear wall mm |
S side to wall mm |
H hearth depth mm |
W hearth width mm |
MAX HEAT av. heat output |
| 215 | 150 | 585 | 400 | 800 | 15.1 kW |
Please Note: Required Minimum Hearth Measurements Only From Firebox Door Opening. Recommended Hearth Size 1100 deep x 1200 wide.

Small Bushranger MK3
| A width mm |
B depth mm |
C back to flue centre mm |
overall height mm |
WEIGHT approx. | EMISSION FACTOR g/kg | HEATING CAPACITY approx. |
| 550 | 500 | 150 | 820 | 90 kg | 1.6 | 16 sq |
| G cnr to wall mm |
R |
S |
H hearth depth mm |
W hearth width mm |
MAX HEAT av. heat output |
| 150 | 150 | 475 | 300 | 700 | 12.3 kW |
Please Note: Required Minimum Hearth Measurements Only From Firebox Door Opening. Recommended Hearth Size 1100 deep x 1200 wide.
All heaters must be installed by a qualified installer.
Installation, Hearth and Flue Requirements
Ned Kelly Woodheaters comply with AS/NZS 2918:2001 sections 3.3.2 & 3.3.3
The flue kit must be installed in accordance with AS/NZS 2918:2001. Although a Shamic standard triple flue kit was used for the compliance testing of Ned Kelly Woodheaters any brand can be used providing the unit conforms to AS/NZS 2918:2001. The minimum flue height is 4.6m above the floor protector.
Please Note: Heating capacities may vary according to type of firewood used and moisture content, climatic conditions, home design and insulation levels. All installation requirements stated are a minimum recommendation.