Bushranger Specifications and Installation Details

Large Bushranger MK2

A
width
mm
B
depth
mm
C
back to flue centre
mm
overall height
mm
WEIGHT approx. EMISSION FACTOR g/kg HEATING CAPACITY approx.
630 600 150 920 124 kg 2.3 30 Sq

 

G
cnr to wall mm
R
rear wall mm
S
side to wall mm
H
hearth depth mm
W
hearth width mm
MAX HEAT
av. heat output
215 150 585 400 800 15.1 kW

 

Please Note: Required Minimum Hearth Measurements Only From Firebox Door Opening. Recommended Hearth Size 1100 deep x 1200 wide.

Small Bushranger MK3

A
width
mm
B
depth
mm
C
back to flue centre
mm
overall height
mm
WEIGHT approx. EMISSION FACTOR g/kg HEATING CAPACITY approx.
550 500 150 820 90 kg 1.6 16 sq

 

G
cnr to wall
mm

R
rear wall
mm

S
side to wall
mm

H
hearth depth
mm
W
hearth width
mm
MAX HEAT av. heat output
150 150 475 300 700 12.3 kW

 

Please Note: Required Minimum Hearth Measurements Only From Firebox Door Opening. Recommended Hearth Size 1100 deep x 1200 wide.

 

All heaters must be installed by a qualified installer.

Installation, Hearth and Flue Requirements

Ned Kelly Woodheaters comply with AS/NZS 2918:2001 sections 3.3.2 & 3.3.3

The flue kit must be installed in accordance with AS/NZS 2918:2001. Although a Shamic standard triple flue kit was used for the compliance testing of Ned Kelly Woodheaters any brand can be used providing the unit conforms to AS/NZS 2918:2001. The minimum flue height is 4.6m above the floor protector.

Please Note: Heating capacities may vary according to type of firewood used and moisture content, climatic conditions, home design and insulation levels. All installation requirements stated are a minimum recommendation.

 

 

Model Specifications and Installation Details:

Compliance Certificates: